Block %2 Spline For Orientation Not Possible; Illegal Reference System For Cartesian Manual Traverse; Block %2 Illegal Tool Carrier Number Programmed Or Declared (Md); Block %2 Illegal Tool Carrier Rotation - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

14147
[Channel %1: ] Block %2 spline for orientation not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If an orientation has been programmed while BSPLINE is active, the interpolation of
tool orientation must be interpolated via a 2nd space curve. This means that G code ORICURVE
must be active for the interpolation of the orientation.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Change the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14148
[Channel %1: ] Illegal reference system for Cartesian manual traverse
Parameters:
%1 = Channel number
Definitions:
In the SD42650 $SC_CART_JOG_MODE, an illegal value has been entered for the reference system with Cartesian
manual travel.
Reaction:
Alarm display.
Remedy:
Enter a permitted value in the SD42650 $SC_CART_JOG_MODE.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14150
[Channel %1: ] Block %2 illegal tool carrier number programmed or declared (MD)
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A toolholder number was programmed which is negative or greater than the MD18088
$MN_MM_NUM_TOOL_CARRIER.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Program valid toolholder number or adapt MD 18088
$MN_MM_NUM_TOOL_CARRIER.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14151
[Channel %1: ] Block %2 illegal tool carrier rotation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A toolholder was activated with an angle of rotation unequal to zero, although the associated axis is not defined. A
rotary axis is not defined when all three direction components are zero.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Set angle of rotation to zero, or define the associated rotary axis.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms