Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15166
[Channel %1: ] User system asup _N_ASUP_SPF not available
Parameters:
%1 = Channel number
Definitions:
By means of the MD11610 $MN_ASUP_EDITABLE the function "User-defined system asup" has been activated.
However, the relevant user program could not be found in the specified search path:
- 1. /_N_CUS_DIR/_N_ASUP_SPF
- 2. /_N_CMA_DIR/_N_ASUP_SPF
The default system asups are used.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Load the user-defined system asup in /_N_CUS_DIR/_N_ASUP_SPF or /_N_CMA_DIR/_N_ASUP_SPF laden.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15170
[Channel %1: ] Block %2 program %3 could not be compiled
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Definitions:
An error has occurred in compile mode. The (compiler) error message refers to the program specified here.
Reaction:
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15171
[Channel %1: ] Block %2 compiled program %3 older than the relevant subroutine
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Compiled program file name
Definitions:
When calling a precompiled subroutine, it was noticed that the compiled program is older than the relevant SPF file.
The compiled program was deleted and during start the subroutine is executed instead of the compiled program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Perform another precompilation.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms