Block %2 Error In Initialization Sequence In Function %3 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Proceed as in the case of a system error.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14710
[Channel %1: ] Block %2 error in initialization sequence in function %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier of the function which caused the error
Definitions:
Initialization blocks are generated (or not) after control power-up, (program) RESET and (program) START, depending
on the settings in machine data MD20110 $MC_RESET_MODE_MASK and MD20112 $MC_START_MODE_MASK.
Errors can occur because of incorrect machine data settings. The errors are output with the same error messages as
would appear if the function had been incorrectly programmed in the part program.
This alarm is also generated in order to indicate that an error relates to the initialization sequence.
Parameter %3 specifies which function triggers the alarm:
Control power-up and (program) RESET:
Value:
0: Error during synchronization preprocessing/main run
1: Error on selection of tool length compensation
2: Error on selection of transformation
3: Error on selection of work offset
The macro definitions and cycle interfaces are also read in during the power-up procedure. If an error occurs here, this
is indicated by value = 4, or value = 5
6: Error creating 2 1/2 D protection zones during power up.
(Program) START:
Value
100: Error during synchronization preprocessing/main run
101: Error on selection of tool length compensation
102: Error on selection of transformation
103: Error on selection of synchronized spindle
104: Error on selection of work offset
Particularly when tool management is active, it is possible that a tool on the spindle or the toolholder is disabled but
still needs to be activated.
These tools are automatically activated on RESET. On START, machine data MD22562
$MC_TOOL_CHANGE_ERROR_MODE can be used to specify whether an alarm is to be generated or an automatic
bypass strategy selected.
If the parameter contains 3 values from 200 to 203, this means that an insufficient number of NC blocks is available
for NC block preparation on certain commands (ASUB start, overstore selection, teach-in).
Remedy: Increase machine data MD28070 $MC_MM_NUM_BLOCKS_IN_PREP.
Reaction:
Interpreter stop
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
191