SINAMICS alarms
208000
<location>TB: +/-15 V power supply faulted
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, CU_I_COMBI, CU_I_SINUMERIK_828, CU_LINK, CU_NX_828,
HUB, SIC_COMBI, SIC_SINUMERIK_828, TM120, TM54F_MA, TM54F_SL
Reaction:
NONE (OFF1, OFF2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
Terminal Board 30 detects an incorrect internal power supply voltage.
Fault value (r0949, interpret decimal):
0: Error when testing the monitoring circuit.
1: Fault in normal operation.
Remedy:
- replace Terminal Board 30.
- replace Control Unit.
208010
<location>TB: Analog-digital converter
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, CU_I_COMBI, CU_I_SINUMERIK_828, CU_LINK, CU_NX_828,
HUB, SIC_COMBI, SIC_SINUMERIK_828, TM120, TM54F_MA, TM54F_SL
Reaction:
NONE (OFF1, OFF2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The analog/digital converter on Terminal Board 30 has not supplied any converted data.
Remedy:
- check the power supply.
- replace Terminal Board 30.
213010
<location>Licensing function module not licensed
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, CU_LINK, HUB, SERVO_COMBI, SERVO_SINUMERIK828,
SIC_COMBI, SIC_SINUMERIK_828, TM120, TM54F_MA, TM54F_SL
Reaction:
OFF1
Acknowledge:
IMMEDIATELY
Cause:
At least one function module which is under license does not have a license.
Fault value (r0949, interpret hexadecimal):
Bit x = 1: The corresponding function module does not have a license.
Note:
Refer to p0108 or r0108 for the assignment between the bit number and function module.
Remedy:
- enter and activate the license key for function modules under license (p9920, p9921).
- if necessary, de-activate unlicensed function modules (p0108, r0108).
230001
<location>Power unit: Overcurrent
Message value:
Fault cause: %1 bin
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828
Reaction:
OFF2
Acknowledge:
IMMEDIATELY