[Channel %1: ] Block %2 %3 Not Available With Tool Management; Block %2 Nc Command Setmth Not Allowed; Block %2 Command '%3' Cannot Be Programmed; Function '%4' Has Not Been Activated - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
6433

[Channel %1: ] Block %2 %3 not available with tool management

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The symbol variable specified in %3 is not available with active tool management. The function GELSELT should be
used with $P_TOOLP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify program. If $P_TOOLP has been programmed, the GETSELT function should be used instead.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
6434
[Channel %1: ] Block %2 NC command SETMTH not allowed because tool holder
function not active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No master toolholder has been defined for the initial state (MD20124 $MC_TOOL_MANAGEMENT_TOOLHOLDER
= 0), therefore no toolholder is available. The NC command SETMTH has neither been defined. In this setting, the tool
change is carried out referring to the master spindle. The master spindle is set with SETMS.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program (delete or replace SETMHT) or enable toolholder function via machine data.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
6436
[Channel %1: ] Block %2 command '%3' cannot be programmed. Function '%4' has not
been activated.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Function identifier
Definitions:
The command cannot be programmed due to the lack of a function enable or activation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
58
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents