Arithmetic Error In User Program: Type %2 Network %1; Maximum Number Of Subroutine Levels Exceeded: %2 Network %1; Error Affecting Indirect Addressing: %2, Network %1; Plc User Program Is Incorrect/Profinet - I/O Ramp-Up Fault Type: %1 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

400010

Arithmetic error in user program: Type %2 network %1

Definitions:
Check user program in the specified network.
%1Network number, module ID
%2 = 1:Division by zero using fixed-point arithmetic
2:Floating-point arithmetic
Reaction:
PLC Stop
Remedy:
Change user program.
Program
Switch control OFF - ON.
Continuation:
400011

Maximum number of subroutine levels exceeded: %2 network %1

Definitions:
%1Network number
%2Module ID
Check user program in the specified network.
Reaction:
PLC Stop
Remedy:
Change user program.
Program
Switch control OFF - ON.
Continuation:
400012

Error affecting indirect addressing: %2, network %1

Definitions:
%1Network number
%2Module ID
Check user program in the specified network.
Reaction:
PLC Stop
Remedy:
Change user program.
Program
Switch control OFF - ON.
Continuation:
400013
PLC user program is incorrect
Definitions:
The PLC user program in the control is incorrect or is not available.
Reaction:
PLC Stop
Remedy:
Reload PLC user program.
Program
Switch control OFF - ON.
Continuation:
400014
Profinet - I/O ramp-up fault type: %1
Definitions:
%1: 1Profinet - I/O not ramped-up
2Software version NC - PLC incompatibility
3Number of slots per function exceeded
4Profinet I/O server not ready
Reaction:
PLC Stop
Remedy:
Types 1 to 3:Report error to Siemens
Type 4:828D – Check and/or replace PCU hardware and/or check MD 11240
Program
Switch control OFF - ON.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
PLC alarms
905

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents