400010
Arithmetic error in user program: Type %2 network %1
Definitions:
Check user program in the specified network.
%1Network number, module ID
%2 = 1:Division by zero using fixed-point arithmetic
2:Floating-point arithmetic
Reaction:
PLC Stop
Remedy:
Change user program.
Program
Switch control OFF - ON.
Continuation:
400011
Maximum number of subroutine levels exceeded: %2 network %1
Definitions:
%1Network number
%2Module ID
Check user program in the specified network.
Reaction:
PLC Stop
Remedy:
Change user program.
Program
Switch control OFF - ON.
Continuation:
400012
Error affecting indirect addressing: %2, network %1
Definitions:
%1Network number
%2Module ID
Check user program in the specified network.
Reaction:
PLC Stop
Remedy:
Change user program.
Program
Switch control OFF - ON.
Continuation:
400013
PLC user program is incorrect
Definitions:
The PLC user program in the control is incorrect or is not available.
Reaction:
PLC Stop
Remedy:
Reload PLC user program.
Program
Switch control OFF - ON.
Continuation:
400014
Profinet - I/O ramp-up fault type: %1
Definitions:
%1: 1Profinet - I/O not ramped-up
2Software version NC - PLC incompatibility
3Number of slots per function exceeded
4Profinet I/O server not ready
Reaction:
PLC Stop
Remedy:
Types 1 to 3:Report error to Siemens
Type 4:828D – Check and/or replace PCU hardware and/or check MD 11240
Program
Switch control OFF - ON.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
PLC alarms
905