<location>TM54F: Test stop required
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
NONE
Cause:
- after powering up the drive, a test stop has still not been carried out.
- a new test stop is required after commissioning.
- the time to carry out the forced checking procedure (test stop) has expired (p10003).
Remedy:
Initiate test stop (BI: p10007).
235015
<location>TM54F: Communication with drive not established
Message value:
Fault cause: %1 bin
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
NONE
Cause:
Cyclic communication of one or several drives with the Terminal Module 54F (TM54F) is not active.
Fault value (r0949, interpret binary):
Bit 0 = 1: No communication with drive 1.
...
Bit 5 = 1: No communication with drive 6.
For fault value = 0, the following applies:
The number of drive objects specified in p10010 is not equal to the number of drives that have drive-based motion
monitoring functions that have been enabled.
The drive object number for drive n is set in p10010[n-1].
When this fault is present, none of the drives that have drive-based motion monitoring functions operating with TM54F,
are enabled.
Remedy:
For all drive objects specified in p10010, check whether the drive-based motion monitoring functions with TM54F are
enabled (p9601).
235016
<location>TM54F: Net data communication with drive not established
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
NONE
Cause:
The cyclic net data communication within the Terminal Module 54F (TM54F) is still not active.
This message is output after the TM54F master and TM54F slave have booted and is automatically withdrawn as soon
as communications have been established.
If a drive does not communicate with the TM54F, then none of the drives parameterized in p10010 are enabled.
Remedy:
When replacing a Motor Module, carry out the following steps:
- start the copy function for the node identifier on the TM54F (p9700 = 1D hex).
- acknowledge the hardware CRC on the TM54F (p9701 = EC hex).
- save all parameters (p0977 = 1).
- carry out a POWER ON (power off/on) for all components.
The following always applies:
- for all drive objects specified in p10010, check whether the drive-based motion monitoring functions with TM54F are
enabled (p9601).
- check whether fault F35150 is present and if required, remove the cause of the fault.
See also: r10055 (SI TM54F communication status drive-specific)