NCK alarms
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block.
- Check the number of the transformation grouping when calling the part program with the keyword TRAORI(n) (n ...
number of the transformation grouping).
- Enter the machine data for this transformation grouping and then activate by "Power On".
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14101
[Channel %1: ] Block %2 orientation transformation not active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Euler angles or a vector have been used in programming an orientation and no orientation transformation is active,
i.e. the keyword TRAORI(n) (n ... number of transformation grouping) is missing.
Example of correct transformation programming:
N100 ... TRAORI(1)
N110 G01 X... Y... ORIWKS
N120 A3... B3... C3...
N130 A3... B3... C3...
:
N200 TAFOOF
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Before the transformation is applied, the number of the transformation grouping must be specified with the keyword
TRAORI(n) (n is between 1 and 4).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14102
[Channel %1: ] Block %2 polynominal degree greater than 5 programmed for
orientation vector angle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During polynomial interpolation for the orientation vector, a polynomial degree larger than 5 has been programmed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14104
[Channel %1: ] Block %2 Active transformation allows neither vector programming nor
interpolation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The active orientation transformation does allow neither the programming of
vectors for tool orientation nor the vector interpolation
(ORIVECT, ORICONxx, usw) of the orientation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.