NCK alarms
4112

Servo cycle changed to %1 ms

Parameters:
%1 = String (new servo cycle time)
Definitions:
For PROFIBUS/PROFINET only:
MD10060 $POSCTRL_SYSCLOCK_TIME_RATIO has been modified because of the modified DP cycle in the SDB
(MD10050 $SYSCLOCK_CYCLE_TIME).
Reaction:
Alarm display.
Remedy:
MD10060 $MN_POSCTRL_SYSCLOCK_TIME_RATIO RATIO has been modified.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4113

Sysclock cycle changed to %1 ms

Parameters:
%1 = String (new PLC cycle time)
Definitions:
For PROFIBUS/PROFINET only:
MD10050 $SYSCLOCK_CYCLE_TIME has been modified because of the modified DP cycle in the SDB.
Reaction:
Alarm display.
Remedy:
MD10050 $MN_SYSCLOCK_CYCLE_TIME has been modified.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4114

Error in DP cycle of the SDB

Parameters:
%1 = String (new PLC cycle time)
Definitions:
For PROFIBUS/PROFINET only:
The DP cycle in the SDB contains an error and cannot be set. The default value of
MD10050$MN_SYSCLOCK_CYCLE_TIME is set.
Reaction:
Alarm display.
Remedy:
Correct the SDB
Program
Switch control OFF - ON.
Continuation:
4115

Time ratio communication to Ipo changed to %1

Parameters:
%1 = String (new PLC cycle time)
Definitions:
The value of the MD10072 $MN_COM_IPO_TIME_RATIO has been adapted. This can only occur, if the value of the
machine data is smaller than one and the time thus calculated is no multiple of the position control cycle.
Reaction:
Alarm display.
Remedy:
The MD10072 $MN_COM_IPO_TIME_RATIO has been adapted. Please check to ensure that the calculated value is
correct.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
30