17095
[Channel %1: ] Block %2 invalid value
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt was made to write an invalid value, e.g. zero, into a machine data.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the value assignment, e.g. a value within the value range not equal to zero.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17100
[Channel %1: ] Block %2 digital input/comparator no. %3 not activated
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Input number
Definitions:
Either an attempt was made to read a digital input n via the system variable $A_IN[n] and this input has not been acti-
vated via NCK MD10350 $MN_FASTIO_DIG_NUM_INPUTS; or to read a comparator input via system variable
$A_INCO[n] and this input belongs to a comparator which has not been activated.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program or machine data accordingly.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17110
[Channel %1: ] Block %2 digital output no. %3 not activated
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = No. of output
Definitions:
An attempt was made to read or set a digital NCK output (connector X 121) via the system variable $A_OUT [n] with
the index [n] greater than the specified upper limit in MD10360 $MN_FASTIO_DIG_NUM_OUTPUTS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program index [n] of the system variable $A_OUT [n] only between 0 and the value in MD10360
$MN_FASTIO_DIG_NUM_OUTPUTS.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
270