Block %2 Axis %3 No Measuring System Available; Block %3 Following Axis %2 Overlaid Movement Not Enabled; Block %2 Axis %3 Is The Slave Axis, The Coupling Is Being Opened - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

16770
[Channel %1: ] Block %2 axis %3 no measuring system available
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
One of the following spindle functions has been programmed, the position control requires:
SPCON,
SPOS, SPOSA,
COUPON,
G331/G332.
The position control requires at least one measuring system.
No measuring system has been configured in MD30200 $MA_NUM_ENCS of the programmed spindle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Retrofit a measuring system.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16771
[Channel %1: ] Block %3 following axis %2 overlaid movement not enabled
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
Definitions:
No gear synchronization and no overlay movement can be executed because this is not enabled at the VDI interface.
Reaction:
Alarm display.
Remedy:
Set the NC/PLC interface signal <Freigabe_Folgeachsueberlagerung/> (enable following axis overlay).
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
16772
[Channel %1: ] Block %2 axis %3 is the slave axis, the coupling is being opened
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle
Definitions:
The axis is active as a following axis in a coupling. In REF operating mode, the coupling is opened. The alarm can be
suppressed with MD11410 $MN_SUPPRESS_ALARM_MASK bit 29 = 1 or with CP programming by setting CPMA-
LARM[FAx] bit 0 = 1.
Reaction:
Alarm display.
Remedy:
The coupling will be closed again after having exited the REF operation mode.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
241

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents