NCK alarms
10208
[Channel %1: ] Continue program with NC start
Parameters:
%1 = Channel number
Definitions:
After block search with calculation, the control is in the desired state. The program can now be started with NC Start
or the state can be changed for the time being with overstore/jog.
Reaction:
Interpreter stop
Alarm display.
NC Stop on alarm.
Remedy:
Press NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10209
[Channel %1: ] Internal NC stop after block search
Parameters:
%1 = Channel number
Definitions:
Internal alarm which only initiates the alarm response NC Stop.
The alarm is output in the following situations:
- If MD11450 $MN_SEARCH_RUN_MODE, bit 0 ==1 and the last action block is loaded in the main run after block
search. Alarm 10208 is then activated as a function of the NC/PLC interface signal DB3200 DBX0001.6 (PLC action
finished).
- Search alarm 10208 has been suppressed by the PI service _N_FINDBL (third decade of the parameter supplied
with "2"). Alarm 10209 is set as a function of whether or not a search ASUB has been configured (MD11450
$MN_SEARCH_RUN_MODE bit 1) with the end of the search ASUB or the loading of the last action block in the main
run.
Reaction:
Interpreter stop
NC Stop on alarm.
Remedy:
NC-Start
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10225
[Channel %1: ] command denied
Parameters:
%1 = Channel number
Definitions:
The channel has received a command that cannot be executed.
Reaction:
Alarm display.
Remedy:
Press RESET.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10299
[Channel %1: ] Auto-Repos function is not enabled
Parameters:
%1 = Channel number
Definitions:
The Auto-Repos function (operating mode) was selected in the channel but is not implemented.
Reaction:
Alarm display.
Remedy:
This message is purely informational.
Program
Clear alarm with the Delete key or NC START.
Continuation: