%2 Errors In Ini File; %2 Errors In Gud, Macro Or Ini File; Error During Execution Of Progevent File %3 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
15185
[Channel %1: ] %2 errors in INI file
Parameters:
%1 = Channel number
%2 = Number of detected errors
Definitions:
Errors were found when processing initialization program _N_INITIAL_INI.
This alarm will also be output, if errors are found during editing of _N_INITIAL_INI in the GUD definition files or if errors
are found on ramp-up in the macro definition files.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Correct the INI or DEF file or correct the MD and create
a new INI file (via "Upload").
Program
Switch control OFF - ON.
Continuation:
15186
[Channel %1: ] %2 errors in GUD, macro or INI file
Parameters:
%1 = Channel number
%2 = Number of detected errors
Definitions:
%2 errors were found when processing GUD/macro definition files (DEF files) or initialization files (INI files)
Alarm 15180 has already informed about the corresponding file.
Prior to that the errors shown were reported by error-specific alarms, e.g. 12080 "syntax error".
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify definition file or initialization file
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15187
[Channel %1: ] Error during execution of PROGEVENT file %3.
Parameters:
%1 = Channel number
%2 = Is not used
%3 = PROGEVENT file name
Definitions:
An error has occurred on executing PROGEVENT.
With alarm 15187, the name of the program that was started as PROGEVENT
is displayed. Alarm 15187 is displayed together
with the alarm that describes the error cause. Alarm 15187 is also output
when the alarm occurs in a subroutine started from PROGEVENT.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Correct the PROGEVENT file (subroutine).
Program
Clear alarm with the Delete key or NC START.
Continuation:
210
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0