Maximum Number Of Master Values Exceeded - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Definitions:
The stated instruction is not permitted for the stated type of generic coupling.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16687
[Channel %1: ] Block %2 following axis/spindle %3 type of coupling/instruction %4 is
not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = CP instructions
Definitions:
The stated instruction is not permitted for the stated type of generic coupling.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16688
[Channel %1: ] Block %2 following axis/spindle %3 coupling type %4 maximum number
of master values exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Coupling type
Definitions:
The maximum number of master values has been exceeded for the stated type of generic coupling.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program, reduce number of master values or use a different type of coupling.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16689
[Channel %1: ] Block %2 following axis/spindle %3 coupling type %4 maximum number
of master values exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Coupling type
Definitions:
The maximum number of master values has been exceeded for the stated type of generic coupling.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program, reduce number of master values or use a different type of coupling.
232
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms