611D drive alarms

300406
Problem in the non-cyclic communication for basic address %1, additional information
%2, %3, %4
Definitions:
For PROFIdrive only:
A problem occured during the non-cyclic communication with the logical start address. The additional information
defines the location of the problem. If the logical start address 0 is output, only the additional information is relevant.
Reaction:
Alarm display.
Warning display.
Remedy:
Please inform the authorized personnel/service department. The alarm can be suppressed with MD11411
$MN_ENABLE_ALARM_MASK bit 1 == 0
SIEMENS AG, System Support for A&D MC products, Hotline (Phone: see alarm 1000)
Program
Clear alarm with the Delete key or NC START.
Continuation:
300410

Axis %1 drive %2 error when storing a file (%3, %4)

Parameters:
%1 = NC axis number
%2 = Drive number
%3 = Error code 1
%4 = Error code 2
Definitions:
An attempt to save a data block, e. g. the result of a measuring function, in the file system has failed.
On error code 1 == 291: An error occurred during preparation of the ACC information. Basic information prepared on
the drive contains an error or has an unknown format.
On error code 1 == 292: Memory shortage during preparation of the ACC information.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
- Please inform the authorized personnel/service department.
- Create more space in the file system. It is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of mem-
ory. If these remedies do not work, it will be necessary to increase the number of files per directory or the size of the
file system itself (this will require a complete data backup).
- Change settings of machine data
- 18280 $MM_NUM_FILES_PER_DIR
- 18320 $MM_NUM_FILES_IN_FILESYSTEM
- 18350 $MM_USER_FILE_MEM_MINIMUM
- and, if necessary, of
- 18270 $MM_NUM_SUBDIR_PER_DIR,
- 18310 $MM_NUM_DIR_IN_FILESYSTEM,
- Power On
- Reload saved data
- On error code 1 == 291: Replace the drive software and use version with suitable ACC basic information.
- On error code 1 == 292: Replace the drive software and use fewer different versions of the drive software.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual 07/2010, 6FC5398-8BP40-0BA0
5
891