NCK alarms
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15150
[Channel %1: ] Block %2 reload from external aborted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Execution from external was aborted because the reload buffer does not have enough machine function blocks (tra-
versing blocks, auxiliary function, dwell time etc.). Background: When already executed machine function blocks are
released, memory becomes available in the reload buffer. If machine function blocks are no longer released, nothing
can be reloaded - this results in a deadlock situation.
Example: Definition of extremely long curve tables via execution from external.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Insert machine function blocks in the part progam.
- Increase the size of the reload buffer (MD18360 $MN_MM_EXT_PROG_BUFFER_SIZE).
- Decrease the size of the curve table (Note: Blocks within CTABDEF/CTABEND are not machine function blocks).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15160
[Channel %1: ] Block %2 wrong preprocessing configuration
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A block element is required, but the block element memory is empty.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify the block search configuration in MD28060
$MC_MM_IPO_BUFFER_SIZE (decrease size of IPO buffer if necessary) or MD28070
$MC_MM_NUM_BLOCKS_IN_PREP.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15165
[Channel %1: ] Block %2 error when translating or interpreting Asup %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Definitions:
At part program start and at start of an ASUB under Reset condition, the relevant data of all the ASUBs that can be
activated at that time are processed:
- PLC ASUBs
- With MD20108 $MC_PROG_EVENT_MASK configured event-controlled program calls
- ASUB after block search (MD11450 $MN_SEARCH_RUN_MODE bit 1=1)
- Editable system ASUB ($MN_ASUP_EDITABLE)
If an error occurs (converter or interpreter), alarm 15165 will be output first and then a converter or interpreter alarm
that describes more details of the error. Alarm 15165 will cause an interpreter stop. A compensation block will not be
possible.
206
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms