Spindle %2 Dbb30 Function Not Possible (Cause: Error Code %3); Spindle %2 Error On Gear Stage Change (Cause: Error Code %3) - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

22295
[Channel %1: ] Spindle %2 DBB30 function not possible (cause: error code %3)
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Error code
Definitions:
The function request by PLC via DBB30 interface could not be executed. The cause is specified by the error code.
Error codes:
- Error code 1 : internal use
- Error code 2 : internal use
- Error code 3 : internal use
- Error code 4 : internal use
- Error code 5 : Switchover to command axis not possible
- Error code 6 : Switchover to PLC axis not possible
- Error code 20 : internal use
- Error code 21 : internal use
- Error code 22 : internal use
- Error code 23 : MD 30132 IS_VIRTUAL_AX has been set
- Error code 50 : internal use
- Error code 51 : internal use
- Error code 70 : internal use
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy conflict.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22296
[Channel %1: ] Spindle %2 Error on gear stage change (cause: error code %3)
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Error code
Definitions:
An error occurred during gear stage change. The cause is specified by the error code.
Error codes:
- Error code 1 : internal use
- Error code 2 : internal use
- Error code 3 : internal use
- Error code 4 : internal use
- Error code 5 : Switchover to command axis not possible
- Error code 6 : Switchover to PLC axis not possible
- Error code 20 : internal use
- Error code 21 : internal use
- Error code 22 : internal use
- Error code 23 : MD 30132 IS_VIRTUAL_AX has been set
- Error code 50 : internal use
- Error code 51 : internal use
- Error code 70 : internal use
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy conflict.
Program
Clear alarm with the Delete key or NC START.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
343

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents