Block %2 Number Of Parameters Too High %3; Block %2 Parameter %3 No Longer Possible; Block %2 Dimension Of Parameter %3 Incorrect - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
12340
[Channel %1: ] Block %2 number of parameters too high %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
When calling a function or a procedure (predefined or user-defined) more parameters were transferred than defined.
Predefined functions and procedures: The number of parameters has been set permanently in the NCK.
User-defined functions and procedures: The number of parameters is established by type and name in the definition.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block. Check whether the correct procedure/function has been called. Pro-
gram the number of parameters in accordance with the procedure/function.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12350
[Channel %1: ] Block %2 parameter %3 no longer possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
An attempt has been made to transfer actual parameters although axis parameters located before them have not been
assigned. For procedure or function calls, the assignment of parameters that are no longer required can be omitted if
no more parameters are to be transferred subsequently. Example: N10 FGROUP(X, Y, Z, A, B); a max. of 8 axes pos-
sible The following call-by-value parameters would then be initialized with zero because the space-dependent assign-
ment has been lost on account of the missing axis parameters. Axes that can be omitted and following parameters do
not occur in the predefined procedures and functions.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block. In predefined procedures and functions either remove the following
parameters or transfer any preceding axis parameters. In user-defined procedures and functions, parameter transfer
must be programmed in accordance with the instructions given in the machine manufacturer's programming guide.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12360
[Channel %1: ] Block %2 dimension of parameter %3 incorrect
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
The following possibilities of error must be checked:
- The current parameter is an array, but the formal parameter is a variable
- The current parameter is a variable, but the formal parameter is an array
-
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block. Correct the NC part program in accordance with the cause of error as
listed above.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
120
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents