Please Change Tool %2 Into Magazine. Repeat Data Backup; Tool %2 Is Active, But Not In The Magazine Area Under Consideration - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

22070
[TO unit %1: ] Please change tool %2 into magazine. Repeat data backup
Parameters:
%1 = TO unit
%2 = T number of tool
Definitions:
The alarm can only occur when the tool management function is active in the NCK. (TOOLMAN = tool management)
A data backup of the tool/magazine data has been started. During the backup, the system detected that tools are still
located in the buffer magazine (= spindle, gripper, ...). During the backup, these tools will lose the information which
defines the magazine and location to which they are allocated.
It is therefore practical -assuming that the data are to be stored exactly as before - to ensure that all tools have been
deposited in the magazine before the data backup!!
If this is not the case, some magazine locations will have the 'reserved' status when the data are loaded again. This
'reserved' status must then be reset manually.
For tools with fixed location coding, the loss of the information allocating their location in the magazine has the same
effect as a general empty location search when they are returned to the magazine.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Ensure that no tools are located in the buffer magazine before the data backup. Repeat the data backup after removing
the tools from the buffer magazine.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22071
[TO unit %1: ] Tool %2 is active, but not in the magazine area under consideration
Parameters:
%1 = TO unit
%2 = Tool identifier
%3 = -Not used-
Definitions:
The alarm can only occur when the tool management function is active in the NCK. Either the language command
SETTA has been programmed or the corresponding operator action has been carried out via MMC, PLC, .... The alarm
can also be triggered automatically by the NCK in the wear grouping function. It is detected that more than one tool
from the tool group (tools with the same name/identifier) has the status "active".
The specified tool is either
from a non-considered magazine,
from a non-considered wear grouping,
or from a non-active wear grouping
in a buffer location (is neither magazine nor wear grouping).
Reaction:
Interface signals are set.
Alarm display.
Remedy:
The alarm is intended for information purposes. If only one tool in a group can be active at a time for technological
reasons or for reasons of display, the "active" status must be canceled for the tool causing the error.
Otherwise, the alarm can be ignored or even suppressed via the MD11410 $MN_SUPPRESS_ALARM_MASK.
Typical reasons of display are present, if the operator works with the function 'definite D numbers', which can be dis-
played on Siemens MMC in a definite form only, if exactly one tool from a tool group has the status 'active'.
Before machining can be started or before the SETTA (or corresponding MMC operation, ...) language command is
used, all tools of the magazine should have the status "not active".
One option to achieve this is programming SETTIA (or corresponding MMC operation, ...).
Program
Clear alarm with the Delete key or NC START.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
339

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents