NCK alarms
61712
%[[Channel %1: ] Block %2: %]Infeed DX or DZ is larger than tip length of tool
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check infeed DX or DZ in connection with tip length of the tool in tool management.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61713
%[[Channel %1: ] Block %2: %]Tool radius larger than half the tip width
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check tool radius and tip width of tool (plunge cutter, cutting tool)
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61714
%[[Channel %1: ] Block %2: %]System error contour turning %4
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Call the SIEMENS hotline
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61730
%[[Channel %1: ] Block %2: %]Machining range outside delimitation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check machining range and delimitation
Program
Clear alarm with the RESET key. Restart part program
Continuation:
470
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms