NCK alarms
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block.
Program function without parameter transfer.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12100
[Channel %1: ] Block %2 number of passes %3 not permissible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of passes
Definitions:
The subroutines called with MCALL are modal, i.e. after each block with positional information a routine run is auto-
matically performed once. For this reason, programming of the number of passes under address P is not allowed.
The modal call is effective until another MCALL is programmed, either with a new subroutine name or without (delete
function).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block.
Program the subroutine call MCALL without number of passes.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12110
[Channel %1: ] Block %2 block syntax cannot be interpreted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The addresses programmed in the block are not permissible together with the valid syntax defining G function, e.g.
G1 I10 X20 Y30 F1000.
An interpolation parameter must not be programmed in the linear block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block.
Check the block structure and correct in accordance with the programming requirements.
Program
Clear alarm with NC START or RESET key and continue the program.