Machine Data %2 Axis %3 Defined Repeatedly As Geometry Axis; [Channel %1:] Maximum Number Of Axes In Channel %1 Exceeded. Limit %2; The Maximum Number Of Activatable Axes Has Been Exceeded (Limit %1) - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
4004
[Channel %1: ] Machine data %2 axis %3 defined repeatedly as geometry axis
Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = Axis index
Definitions:
An axis may only be defined once as a geometry axis.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Correct MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Program
Switch control OFF - ON.
Continuation:
4005
[Channel %1: ] Maximum number of axes in channel %1 exceeded. Limit %2
Parameters:
%1 = Channel number
%2 = Upper limit for the number of axes in the channel
Definitions:
MD20070 $MC_AXCONF_MACHAX_USED defines which machine axes can be used in this channel. This simulta-
neously defines the number of active axes in the channel. This upper limit has been exceeded. Note: The channel axis
gaps may cause certain indices of MD20070 $MC_AXCONF_MACHAX_USED to remain unused and therefore do
not count as active channel axes.
Example:
- CHANDATA(2)
- $MC_AXCONF_MACHAX_USED[0] = 7
- $MC_AXCONF_MACHAX_USED[1] = 8
- $MC_AXCONF_MACHAX_USED[2] = 0
- $MC_AXCONF_MACHAX_USED[3] = 3
- $MC_AXCONF_MACHAX_USED[4] = 2
- $MC_AXCONF_MACHAX_USED[5] = 0
- $MC_AXCONF_MACHAX_USED[6] = 1
- $MC_AXCONF_MACHAX_USED[7] = 0
This channel uses the five machine axes 1, 2, 3, 8, 7, i.e. it has 5 active channel axes.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify MD20070 $MC_AXCONF_MACHAX_USED.
Program
Switch control OFF - ON.
Continuation:
4006

The maximum number of activatable axes has been exceeded (limit %1)

Parameters:
%1 = Number of axes
Definitions:
The sum of the two option data $ON_NUM_AXES_IN_SYSTEM and $ON_NUM_ADD_AXES_IN_SYSTEM must not
exceed the maximum number of axes in the system.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
20
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents