Block %2: No Length L1 Entered Under D...; Block %2: Incorrect D Number / Dresser D Field Active; Block %2: Incorrect Grinding Wheel Type Entered; Incorrect Grinding Wheel Reference Point Selected - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

61533
[Channel %1: ] Block %2: No length L1 entered under D...
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE416, CYCLE420
Remedy:
Enter length L1 in the tool offset D of the grinding wheel
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61540
[Channel %1: ] Block %2: Incorrect D number / dresser D field active
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE401, CYCLE402, CYCLE403, CYCLE443
Remedy:
A tool D number must be programmed that is < _GC_DNUM
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61541
[Channel %1: ] Block %2: Incorrect grinding wheel type entered
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE432, CYCLE434, CYCLE435, CYCLE436,
CYCLE438, CYCLE439, CYCLE444, CYCLE447
Remedy:
Select a valid grinding wheel type in tool management
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61542
[Channel %1: ] Block %2: Incorrect grinding wheel reference point selected when
selecting the dresser coordinate system
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE435, CYCLE441, CYCLE447
Remedy:
A tool D number must be programmed that is < _GC_DNUM
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61543
[Channel %1: ] Block %2: Incorrect dresser selected when selecting the dresser
coordinate system
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE402, CYCLE435, CYCLE442, CYCLE447
Remedy:
A dresser number >0 and <4 must be selected
Program
Clear alarm with the RESET key. Restart part program