Identifier %1 Used Several Times In Machine Data %2 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
4011
[Channel %1: ] Invalid identifier used in machine data %2[%3]
Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
Definitions:
When defining names in the channel-specific tables for geometry axes and channel axes, one of the following syntax
rules for the identifier to be entered has been violated:
- The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numerical extension.
- The identifier must begin with any 2 capital letters but not with $ (reserved for system variables).
- The identifier must not be a keyword of the NC language (e.g. SPOS).
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Enter the identifier for user-defined names with correct syntax in the displayed MD
- Geometry axes: MD20060 $MC_AXCONF_GEOAX_NAME_TAB
- Channel axes:
Program
Switch control OFF - ON.
Continuation:
4012
Invalid identifier used in machine data %1[%2]
Parameters:
%1 = String: MD identifier
%2 = Index: MD array
Definitions:
The selected identifier is invalid. Valid identifiers are:
- AX1 - AXn: Machine axis identifiers
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use the correct identifier.
Program
Switch control OFF - ON.
Continuation:
4020

Identifier %1 used several times in machine data %2

Parameters:
%1 = String: Name of identifier
%2 = String: MD identifier
Definitions:
When determining a name in the NCK tables (arrays) for: machine axes, Euler angles, direction vectors, normal vec-
tors, interpolation parameters and intermediate point coordinates, an identifier has been used that already exists in
the control.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
22
MD20080 $MC_AXCONF_CHANAX_NAME_TAB
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents