System reactions
8.1 System reactions to SINUMERIK alarms
Identifier
NOREADY | BAGREACTIONVIEW
Effects
Mode group ready off: Active fast braking (i.e. with maximum braking current) of the drives in this
mode group, the controller enable of the NC axes involved is deleted.
•
Mode group not ready.
Identifier
NOREADY
Effects
Channel ready off: Active fast braking (i.e. with maximum braking current) of the drives in this channel,
the controller enable of the NC axes involved is deleted.
•
Channel not ready.
Identifier
NONCSTART
Effects
It is not possible to start a program in this channel.
•
NC start inhibit in this channel.
Identifier
NOREFMARK
Effects
The axes in this channel have to be referenced again.
•
Re-reference axes in this channel.
Identifier
SETVDI
Effects
VDI interface signal alarm is set.
•
Interface signals are set.
Identifier
SHOWALARM
Effects
Alarm is displayed on the HMI.
•
Alarm display.
Identifier
STOPBYALARM
Effects
Ramp stop of all channel axes.
•
NC stop for alarm.
Identifier
STOPATENDBYALARM
Effects
Stop at end of block.
•
NC Stop for alarm at end of block.
932
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms