Siemens Sinamics S120 Diagnostic Manual page 932

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

System reactions
8.1 System reactions to SINUMERIK alarms
Identifier
NOREADY | BAGREACTIONVIEW
Effects
Mode group ready off: Active fast braking (i.e. with maximum braking current) of the drives in this
mode group, the controller enable of the NC axes involved is deleted.
Mode group not ready.
Identifier
NOREADY
Effects
Channel ready off: Active fast braking (i.e. with maximum braking current) of the drives in this channel,
the controller enable of the NC axes involved is deleted.
Channel not ready.
Identifier
NONCSTART
Effects
It is not possible to start a program in this channel.
NC start inhibit in this channel.
Identifier
NOREFMARK
Effects
The axes in this channel have to be referenced again.
Re-reference axes in this channel.
Identifier
SETVDI
Effects
VDI interface signal alarm is set.
Interface signals are set.
Identifier
SHOWALARM
Effects
Alarm is displayed on the HMI.
Alarm display.
Identifier
STOPBYALARM
Effects
Ramp stop of all channel axes.
NC stop for alarm.
Identifier
STOPATENDBYALARM
Effects
Stop at end of block.
NC Stop for alarm at end of block.
932