16915
[Channel %1: ] Action %2<ALNX> not allowed in the current block
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
If traversing blocks are interrupted by asynchronous subroutines, then it must be possible for the interrupted program
to continue (reorganization of block processing) after termination of the asynchronous subroutine.
The 2nd parameter describes which action wanted to interrupt block processing.
Reaction:
Alarm display.
Remedy:
Let the program continue to a reorganized NC block or modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16916
[Channel %1: ] Repositioning: action %2<ALNX> not allowed in the current state
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Repositioning of block processing is presently not possible. A mode change cannot take place.
The 2nd parameter describes which action should be used to perform repositioning.
Reaction:
Alarm display.
Remedy:
Let the program continue to a repositioned NC block or modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16919
[Channel %1: ] Action %2<ALNX> is not allowed due to a pending alarm
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
This action cannot be performed due to an alarm, or the channel is in the fault condition.
Reaction:
Alarm display.
Remedy:
Press the RESET key.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16920
[Channel %1: ] Action %2<ALNX> is already active
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
An identical action is still being processed.
Reaction:
Alarm display.
Remedy:
Wait until the previous procedure has been terminated and then repeat the operation.
Program
Clear alarm with the Delete key or NC START.
Continuation:
252
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents