NCK alarms
61527
[Channel %1: ] Block %2: Grinding wheel radius >= workpiece radius
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE414
Remedy:
Change grinding wheel radius or workpiece radius
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61529
[Channel %1: ] Block %2: Dimensional notation INCH programmed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE412, CYCLE413,
CYCLE414, CYCLE415, CYCLE420
Remedy:
Basic system MD $MN_SCALING_SYSTEM_IS_METRIC does not correspond to programmed G command (G group
13).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61530
[Channel %1: ] Block %2: Default longitudinal position incorrect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE420
Remedy:
Check longitudinal position parameter
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61531
[Channel %1: ] Block %2: Longitudinal position not registered in Z
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE420
Remedy:
Increase infeed path parameter
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61532
[Channel %1: ] Block %2: Value for _LAGE is incorrect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE414
Remedy:
Correct parameter content for _LAGE
Program
Clear alarm with the RESET key. Restart part program