No Assign Between Toolholder/Spindle No. = %3/Buffer Mag Location %4; Block %2 Tool Change Not Possible. No Distance Relation Available; Magazine Location No. %3 Not Available In Magazine %4 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

6453
[Channel %1: ] Block %2 tool change not possible. No assignment between toolholder/
spindle no. = %3 and buffer magazine location %4
Parameters:
%1 = Channel ID
%2 = Block number, label
%3 = Spindle no.
%4 = Location no.
Definitions:
The desired tool change is not possible. No relation has been defined between the toolholder/spindle number and the
buffer magazine location (Location No.)
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the magazine data ($TC_MLSR) have been defined correctly.
- Check whether the alarm-causing program command _ e.g. TCI _ has been programmed correctly.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
6454
[Channel %1: ] Block %2 tool change not possible. No distance relation available.
Parameters:
%1 = Channel ID
%2 = Block number, label
Definitions:
The desired tool change is not possible. Neither the spindle nor the buffer magazine location have a distance relation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the magazine data ($TC_MDP2) have been defined correctly.
- Check whether the alarm-causing program command _ e.g. TCI _ has been programmed correctly.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
6455
[Channel %1: ] Block %2 tool change not possible. Magazine location no. %3 not
available in magazine %4
Parameters:
%1 = Channel ID
%2 = Block number, label
%3 = Magazine location number
%4 = Magazine number
Definitions:
The desired tool change is not possible. The indicated magazine location is not available in the indicated magazine.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the causing program command - e.g. TCI - has been parameterized correctly.
- Check whether magazine data have been defined correctly. ($TC_MAP6 and $TC_MAP7 of the intermediate location
magazine)
Program
Clear alarm with NC START or RESET key and continue the program.