Block %2: External Tool Diameter Too Small; Block %2: %]Chamfer Width Too Small; Block %2: %]Chamfer Width - Tool Radius - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Remedy:
The machining direction must be selected to match the delimitations.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61269
[Channel %1: ] Block %2: External tool diameter too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Incorrect tool definition.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check angle and diameter of the tool used.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61270
%[[Channel %1: ] Block %2: %]Chamfer width too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Chamfer width selected too small.
Alarm triggered by the following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Increase the chamfer width.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61271
%[[Channel %1: ] Block %2: %]Chamfer width > tool radius
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Chamfer width larger than tool radius.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a larger tool.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
422
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms