22322
[Channel %1: ] Axis %2 PRESET: illegal value
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The entered Preset value is too large (number format overflow).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use more realistic (smaller) Preset values.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
22400
[Channel %1: ] Option 'contour handwheel' not set
Parameters:
%1 = Channel number
Definitions:
The function 'contour handwheel' was activated without the neccesary option.
If the alarm occurs
- on selection of the contour handwheel via the PLC, then the contour handwheel has to be deselected in order to
continue with the program
- on account of programming FD=0, then the program can be corrected and continued with the compensation block
and NCSTART.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Set option
- Cancel the activation of the function 'contour handwheel'
- Modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
25000

Axis %1 hardware fault of active encoder

Parameters:
%1 = Axis name, spindle number
Definitions:
The signals of the currently active position actual value encoder (NC/PLC interface signal DB380x DBX0001.5 = 1
(Position measuring system 1) or DB380x DBX0001.6 = 1 (Position measuring system 2)) are missing, do not have
the same phase, or exhibit grounding/short-circuit.
The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready).
For PROFIdrive only:
MD36310 $MA_ENC_ZERO_MONITORING >100 replaces the existing PowerOn alarm by the Reset alarm 25010.
Reaction:
Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Axes of this channel must be re-referenced.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
Please inform the authorized personnel/service department. Check measuring circuit connectors for correct contact-
ing. Check encoder signals and replace the encoder if faults are found.
Monitoring can be switched off by setting MD36310 $MA_ENC_ZERO_MONITORING[n] to 100 (n = encoder number:
1,2).
Program
Switch control OFF - ON.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0