List of actions
/FASTMODESWITCHTOAPROGMODE/ No. 126
Definitions:
Implicit mode change back at the end of a "JOG motion" started in automatic mode.
See also $MN_JOG_MODE_MASK
Not permitted if:
1. A channel has left the mode group on account of an interrupt.
2. Overstoring
Possible actions:
1. Cancel the program with the Reset button or wait until the interrupt has finished.
4. Deselect overstore
/SIMULATIONBLOCKSEARCHRUN/ No. 127
Definitions:
Simulation block search is to be started, that means the results of the computation will only be displayed on the HMI,
NO traverse after block search.
Not permitted if:
1. The NCK channel is not in RESET
Possible action:
1. Press reset
/EXECPROGPART/ No. 128
Definitions:
Execute program area has been rejected.
Not permitted if:
1. The channel is not in RESET.
2. The channel is not in Automatic.
Possible actions:
1. Press reset.
2. Switch to automatic.
/SYNTAXCHECK_SELECT/ No. 129
Definitions:
Selection of PI service syntax check "_N_CHKSEL" has been rejected.
Not permitted if:
1. The channel is not in RESET
Possible action:
1. Press reset
/SYNTAXCHECK_RUN/ No. 130
Definitions:
Starting of PI service syntax check "_N_CHKRUN" has been rejected.
Not permitted if:
1. The channel is not in RESET
Possible action:
1. Press reset
/SYNTAXCHECK_ABORT/ No. 131
Definitions:
Starting of PI service syntax check "_N_CHKABO" has been rejected.
Not permitted if:
Should not occur.