Axis %2 Coord System-Specific Working Area Limit %3 End Position %4; Contour Handwheel: Traverse Direction Not Allowed; Axis %1 Travel To Fixed Stop Not Possible. Check Programming/Axis Data - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

20082
[Channel %1: ] Axis %2 coordinate system-specific working area limit %3 end position
%4
Parameters:
%1 = Channel number
%2 = Axis number
%3 = "+" or "-"
%4 = End position
Definitions:
The displayed axis is operated as a "concurrent positioning axis", and the corresponding active coordinate system-
specific working area limitation for the axis is violated. No traversing movement.
With an additional message to alarm 20140, the axis is traversed as a command axis.
Reaction:
Alarm display.
Remedy:
- Specify smaller target position.
- Deactivate working area limitation.
- Set working area limitation differently.
- Retract axis with JOG.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
20085
[Channel %1: ] Contour handwheel: traverse direction or overtravel of beginning of
block not allowed
Parameters:
%1 = Channel number
Definitions:
Travel takes place on the path with the contour handwheel in the opposite direction to the programmed travel direction
and the starting point of the path has been reached at the start of the block.
Reaction:
Alarm display.
Remedy:
Turn the contour handwheel in the opposite direction.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
20090
Axis %1 travel to fixed stop not possible. Check programming and axis data.
Parameters:
%1 = Axis name, spindle number
Definitions:
1. The "Traverse against fixed stop" function has been programmed with FXS[AX]=1 but the axis does not (yet) support
this. Check MD37000 $MA_FIXED_STOP_MODE. This function is not available for gantry axes and simulated axes.
2. On selection, no movement was programmed for axis AX. AX is a machine axis identifier.
3. It is always necessary to program a traversing movement in the selection block for the axis/spindle for which the
"Traverse against fixed stop" function is activated.
The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
- Check the axis type.
- Check MD37000 $MA_FIXED_STOP_MODE.
- Is a machine axis movement missing in the approach block?
Program
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
307

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents