Block%2 Subroutine%3, No Interface Available At Time Of Preprocessing; Block %2 Variable %3 Was Unknown At The Time Of Preprocessing; Block %2 Program %3. Interfaces Could Not Be Built - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
15172
[Channel %1: ] Block %2 subroutine %3. No interface available at time of
preprocessing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Subroutine name
Definitions:
In compilation mode no program interface of the subroutine to be called was available at the time of pre-compilation.
Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify parts program or recreate program interfaces and pre-compile programs again.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15173
[Channel %1: ] Block %2 variable %3 was unknown at the time of preprocessing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Variable
Definitions:
At the time of program precompilation, variable %3 was not known to the control.
Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Correct the part program or introduce the variable at the time of precompilation, i.e. activate the new GUD variable
prior to precompilation. Then restart precompilation.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15175
[Channel %1: ] Block %2 program %3. Interfaces could not be built
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Definitions:
An error has occurred in interface generation mode. The (compiler) error message refers to the program specified
here. In particular when loading new cycle program on the NCK, problems can occur if the value settings in MD18170
$MN_MM_NUM_MAX_FUNC_NAMES and MD18180 $MN_MM_NUM_MAX_FUNC_PARAM are too small.
Reaction:
Alarm display.
Remedy:
- Modify part program.
- If new cycle programs have been loaded on the NCK, you will normally need to increase the values of MD18170
$MN_MM_NUM_MAX_FUNC_NAMES and MD18180 $MN_MM_NUM_MAX_FUNC_PARAM. See also the explana-
tions for alarm 6010.
Program
Clear alarm with the Delete key or NC START.
Continuation:
208
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents