SINAMICS alarms
207530
<location>Drive: Drive Data Set DDS not present
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828
Reaction:
NONE
Acknowledge:
NONE
Cause:
The selected drive data set is not available (p0837 > p0180). The drive data set was not changed over.
See also: p0180, p0820, p0821, p0822, p0823, p0824, r0837
Remedy:
- select the existing drive data set.
- set up additional drive data sets.
207531
<location>Drive: Command Data Set CDS not present
Message value:
-
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The selected command data set is not available (p0836 > p0170). The command data set was not changed over.
See also: p0810 (Command Data Set selection CDS bit 0), r0836 (Command Data Set CDS selected)
Remedy:
- select the existing command data set.
- set up additional command data sets.
207541
<location>Drive: Data set changeover not possible
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828
Reaction:
NONE
Acknowledge:
NONE
Cause:
The selected drive data set changeover and the assigned motor changeover are not possible and are not carried out.
For synchronous motors, the motor contactor may only be switched for actual speeds less than the speed at the start
of field weakening (r0063 < p0348).
See also: r0063 (Actual speed smoothed), p0348 (Speed at the start of field weakening Vdc = 600 V)
Remedy:
Reduce the speed below the speed at the start of field weakening.
207550
<location>Drive: Not possible to reset encoder parameters
Message value:
%1
Drive object:
SERVO_COMBI, SERVO_SINUMERIK828
Reaction:
NONE
Acknowledge:
NONE
Cause:
When carrying out a factory setting (e.g. using p0970 = 1), it was not possible to reset the encoder parameters. The
encoder parameters are directly read out of the encoder via DRIVE-CLiQ.
Alarm value (r2124, interpret decimal):
Component number of the encoder involved.
Remedy:
- repeat the operation.
- check the DRIVE-CLiQ connection.