NCK alarms
22280
[Channel %1: ] In block %2: Prog. acceleration path too short %3, %4 required
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Prog. acceleration path
%4 = Required acceleration path
Definitions:
In order to stay within the programmed acceleration path, the acceleration caused an overload on the thread axis. In
order to accelerate the axis with the programmed dynamic response, the length of the acceleration path must be at
least as large as the value in parameter %4.
The alarm is of the technological type and is output whenever bit 2 in MD11411 $MN_ENABLE_ALARM_MASK is
enabled. The HMI softkey 'Technology support' sets and clears this bit in the MD.
Reaction:
Alarm display.
Remedy:
Modify part program or reset MD11411 $MN_ENABLE_ALARM_MASK bit 2.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22290
[Channel %1: ] Spindle operation for transformed spindle/axis %2 not possible
(reason: error code %3).
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Error code
Definitions:
It is impermissible to start a spindle as long as it is being used by a transformation. Reason: spindle usage in a trans-
formation requires axis operation, which must not be exited.
This alarm may have the following reasons:
- Error code 1 : M3, M4 or M5 per synchronized action;
- Error code 2 : M41 through M45 per synchronized action;
- Error code 3 : SPOS, M19 per synchronized action;
- Error code 11 : DB380x DBX5006.0 (Spindle stop);
- Error code 12 : DB380x DBX5006.1 (Spindle start clockwise rotation);
- Error code 13 : DB380x DBX5006.2 (Spindle start counterclockwise rotation;
- Error code 14 : DB380x DBX5006.4 (Spindle positioning).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Resolve the conflict, for example by deactivating transformation prior to spindle start.
Program
Clear alarm with the Delete key or NC START.