Siemens Sinamics S120 Diagnostic Manual page 920

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

List of actions
Continue selected processing /RESUMEJOGREFDIGIT/ No. 27
Definitions:
Start continue the selected processing,
(VDI signal, NC start)
(JOG or reference point)
Not permitted if:
1. JOG motion is active,
2. An alarm response is pending:
Possible actions:
1. None
2. Execute alarm clear condition.
Deactivate block skip /PROGMODESLASHOFF/ No. 62
Definitions:
Deactivate skip slash blocks
(VDI signal: skip block)
Not permitted if:
1. The nesting depth is too great
Possible actions:
1. Wait until previous ASUB has finished or cancel program
Deactivate program test /PROGTESTOFF/ No. 70
Definitions:
Deactivate program test.
(VDI signal: program test)
Not permitted if:
1. The NCK channel status is not Ready
Possible actions:
2. Cancel program or process with reset button
Deactivate read-in disable /BLOCKREADINHIBIT_OFF/ No. 66
Definitions:
Deactivate read-in disable for main run block.
(VDI signal: read-in disable)
Should not occur in any alarm
Deactivate single block /SINGLEBLOCKOFF/ No. 19
Definitions:
Disable single block.
(VDI signal: deactivate single block)
Should not occur in any alarm
920
which prevents a start,
or compels braking.
or wait for end of program
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms