%1 Option(S) Is/Are Activated Without Setting The License Key; %1 Option(S) Is/Are Activated That Are Not Licensed By The License Key; Wrong License Key Entered Three Times; [Channel %1:] Block %2: Function Not Possible - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
8080

%1 option(s) is/are activated without setting the license key

Parameters:
%1 = Number of non-licensed options
Definitions:
One or more options were activated but no license key was set to prove the purchase of the option(s).
Reaction:
Alarm display.
Remedy:
Generate a license key on the internet at http://www.siemens.com/automation/licence and enter it in the operating
area "Setup", function (HSK) "Licenses".
Program
Clear alarm with the Delete key or NC START.
Continuation:
8081

%1 option(s) is/are activated that are not licensed by the license key

Parameters:
%1 = Number of non-licensed options
Definitions:
One ore more options were activated, that are not licensed by the license key entered.
Reaction:
Alarm display.
Remedy:
Generate a new license key on the internet at http://www.siemens.com/automation/licence and enter it in the operating
area "Setup", function (HSK) "Licenses"..
Program
Clear alarm with the Delete key or NC START.
Continuation:
8082
A wrong license key was entered three times, Power On required before next try.
Definitions:
The license key was entered wrongly at least three times. Before the next input, a new power ON is required.
Reaction:
Alarm display.
Remedy:
Execute NCK Power On and enter the license key (correctly).
Program
Clear alarm with the Delete key or NC START.
Continuation:
8100
[Channel %1: ] Block %2: function not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- Impossible due to embargo regulations:
- 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC, $AA_OVR, $AA_VC and
$AA_OFF) from synchronous actions as well as Continuous Dressing can be programmed only once in a block.
- 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from synchronous action' is not possi-
ble.
- 3. Axis interpolation: The number of axes interpolating with one another must not exceed 4 (this also includes syn-
chronous coupling of axes via synchronous actions "DO POS[X]=$A..." "DO FA[X]=$A...").
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
70
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d