[Channel %1: ] Axis %2 impermissible axis status %3.
Parameters:
%1 = Channel number
%2 = Axis number
%3 = Error ID and gantry unit.
Definitions:
Error ID and gantry unit
- 30XX => Gantry group cannot be closed, as not all gantry axes are in one channel.
- 40XX => Gantry group cannot be closed, as the gantry axes have different axis states (the axis is assigned to the
PLC, for example).
- 50XX => Gantry group is to change channel due to a PLC request, not all gantry axes are known in the new channel.
- 60XX => Gantry group is to be transferred to the channel due to an NC program request, but the channel does not
know all the gantry axes.
- 70XX => Gantry group cannot be closed, as movement is pending for at least one gantry axis.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Local alarm reaction.
Remedy:
Error ID:
- 30XX => assign all gantry axes to the current channel, for example via axis exchange.
- 40XX => set all axes of the gantry group to the same axis state, for example assign all axes to the NC program, or
assign all axes to the PLC.
- 50XX => make all gantry axes known to the required channel.
- 60XX => make all gantry axes known to the required channel.
:end
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10700
[Channel %1: ] Block %2 NCK protection zone %3 violated during automatic or MDI
mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions:
The workpiece-related NCK protection zone has been violated. Note that another tool-related protection zone is still
active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10701
[Channel %1: ] Block %2 channel-specific protection zone %3 violated during
automatic or MDI mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions:
The workpiece-related channel-specific protection zone has been violated. Note that another tool-related protection
zone is still active. The workpiece-related protected area can be traversed after a new NC Start.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
81