Block %2 Tool Management: No Tool Available In Tool Group %3; No Tool Available In Tool Group %3, Program %4 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
22068
[Channel %1: ] Block %2 tool management: no tool available in tool group %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String (identifier)
Definitions:
The specified tool group does not contain a tool which is ready for use and could be used for tool change. It is possible
that all of the tools in question have been set to the 'Disabled' state by the tool monitoring function. The alarm can
occur for example in conjunction with the alarm 14710 (error on INIT block generation). In this specific situation, NCK
attempts to replace the disabled tool located on the spindle with an available replacement tool (which does not exist
in this error condition).
The user must resolve this conflict, for example, by removing the tool located on the spindle from the spindle by issuing
a movement command (e.g. through MMC operation).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Ensure that the specified tool group contains a tool that is ready for use when tool change is requested.
- This can be achieved, for example, by replacing disabled tools, or
- by releasing a disabled tool manually.
- If an alarm occurs on programming TCA: Has the duplo number been programmed >0?
- Check whether the tool data are correctly defined. Have all intended tools in the group been defined/loaded with the
specified identifier?
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
22069
[Channel %1: ] Block %2 tool management: No tool available in tool group %3, program
%4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String (identifier)
%4 = Program name
Definitions:
The specified tool group does not contain a tool which is ready for use and could be used for tool change. It is possible
that all of the tools in question have been set to the 'Disabled' state by the tool monitoring function. Parameter %4 =
program name facilitates the identification of the program containing the programming command (tool selection) that
caused the error. This can be a subprogram or cycle, etc., which can no longer be identified from the display. If the
parameter is not specified, it is the currently displayed program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Ensure that the specified tool group contains a tool that is ready for use when tool change is requested.
- This can be achieved, for example, by replacing disabled tools, or
- by releasing a disabled tool manually.
- Check whether the tool data are correctly defined. Have all intended tools in the group been defined with the specified
identifier and loaded?
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
338
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms