Waiting For A Connection To %1; Start Alarm Acquisition - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

150202

Waiting for a connection to %1

Parameters:
%1 = Source URL of the component involved
Definitions:
The operator panel is connected to the NC and PLC by a communications bus.
This alarm occurs if the MMC is started for the first time and the NC/PLC ramp-up has not yet finished or the commu-
nication to these components is faulty.
In conjuncction with this alarm, all display values connected with the NC/PLC become invalid.
Such faults are normal while the controls are starting up (e.g. after resetting).
Reaction:
Alarm display.
Remedy:
The alarm disappears automatically as soon as the fault situation has ended.
If this alarm is continuously present, a wide variety of faults may be the cause. (e.g. wire breakage, NC/PLC not
ramped up, faulty address/data transfer rate configuration of one of the bus nodes, etc.).
Program
Internal
Continuation:
150204

----- Start alarm acquisition -----

Definitions:
The alarm indicates the start or restart of alarm acquisition in the alarm log.
If the alarm log has been configured so that it is persistently written into the file system, a further alarm is written into
the log at each new start. The alarm thus separates the individual time intervals during which alarm acquisition is
active.
The coming and going time stamps are identical, and correspond to the time of the start/restart of the alarm acquisition.
The alarm is only visible in the alarm log.
Reaction:
Alarm display.
Remedy:
The alarm can but need not be deleted as it is only visible in the alarm log.
Program
Internal
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0