NCK alarms
8030
[Channel %1: ] Block %2 option 'interpolation of more than %3 axes' not set
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of permissible axes
Definitions:
The option for the number of interpolating axes does not correspond to the number of axes programmed in the inter-
polation group.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Option: "Interpolation of more than 4 axes" (the number of axes permitted can be set in this option) or, in the part pro-
gram, program up to as many axes as are permitted by the configuration of the controller.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8031
[Channel %1: ] Block %2 axis %3: Axis has no IPO functionality
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle number
Definitions:
An axis/spindle that has been defined as a special axis/auxiliary spindle (see MD30460
$MA_BASE_FUNCTION_MASK bit8), should be operated as an interpolating axis.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define axis as interpolating axis (see MD30460 $MA_BASE_FUNCTION_MASK bit8) or change part program
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8037

'Activate APC/Number of current setpoint filters' option not set.

Definitions:
More than six current setpoint filters were activated in the drive, although the corresponding option had not been set.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Buy option
- Deactivate the 'Advanced Positioning Control' (APC) function in the drive.
- Set a maximum of six current setpoint filters in the drive.
Program
Switch control OFF - ON.
Continuation:
8040

Machine data %1 reset, corresponding option is not set

Parameters:
%1 = String: MD identifier
Definitions:
A machine data has been set that is locked by an option.
Reaction:
Alarm display.
68
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms