NCK alarms
14139
[Channel %1: ] Block %2 Polynomial for angle of rotation PO[THT] is not permitted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A polynomial for the angle of rotation of orientation (PO[THT]) can only be programmed, if the active transformation
supports it.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Change the NC program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14140
[Channel %1: ] Block %2 position programming without transformation not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Position information was programmed for an axis position but no transformation was active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14144
[Channel %1: ] Block %2 PTP movement not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The PTP G code was programmed for a movement other than G0 or G1.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14146
[Channel %1: ] Block %2 CP or PTP movement without transformation not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The CP or PTP G code was programmed for a movement but no transformation was active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation: