File %1 Lost; Value Of The Machine Data %2%3 Is Too Low; Block %1 Invalid Protection Level For Command %2; [Channel %1: ] Option 'Interrupt Routines' Not Set - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
6693

File %1 lost

Parameters:
%1 = File name
Definitions:
Due to a power failure, a file change could not be terminated properly. The file is lost.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Import the file again.
Program
Switch control OFF - ON.
Continuation:
6700
[Channel %1: ] Value of the machine data %2%3 is too low
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, field index
Definitions:
The MD28302 $MC_MM_PROTOC_NUM_ETP_STD_TYP specifies the number of default event types for the proto-
col users. However, more types are used than configured.
Reaction:
Alarm display.
Remedy:
Increase MD28302 $MC_MM_PROTOC_NUM_ETP_STD_TYP.
Program
Clear alarm with the Delete key or NC START.
Continuation:
7500
Block %1 invalid protection level for command %2 (protection level act.: %3 prog.: %4)
Parameters:
%1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
Definitions:
On assigning a protection level for a parts program command via REDEF command
- an impermissible parts program command has been programmed
- a protection level has been programmed that is logically smaller (larger in value) than the protection level currently
applicable for this command.
- the relevant definition file has not been protected sufficently against write access. The write protection of the file must
be at least as high as the highest protection level that has been assigned to a parts program command in this definition
file.
Reaction:
Alarm display.
Remedy:
Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UACCESS_DEF-CESS_ DEF.
Please see the Siemens Programming Guide or the OEM documentation for the language commands permissible for
the relevant system configurations.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8000

[Channel %1: ] Option 'Interrupt routines' not set

Parameters:
%1 = Channel number
Definitions:
Fast NCK inputs are required for the input signals in order to activate the interrupt routines and rapid lift from contour.
This function is not included in the basic version and must be retrofitted when needed.