62500
[Channel %1: ] Block %2: GWPS has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy:
Check limit value for GWPS and program a lower value in the NC program if necessary
Program
Clear alarm with the Delete key or NC START.
Continuation:
62501
[Channel %1: ] Block %2: Speed has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy:
Check limit value for speed and program a lower value in the NC program if necessary
Program
Clear alarm with the Delete key or NC START.
Continuation:
62502
[Channel %1: ] Block %2: Dresser %4, GWPS has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy:
Check limit value for GWPS and program a lower value in the NC program if necessary
Program
Clear alarm with the Delete key or NC START.
Continuation:
62503
[Channel %1: ] Block %2: Dresser %4, speed has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy:
Check limit value for speed and program a lower value in the NC program if necessary
Program
Clear alarm with the Delete key or NC START.
Continuation: