Activate single block /SINGLEBLOCKSTOP/ No. 18
Definitions:
Activate single block.
(VDI signal: activate single block)
Should not occur in any alarm
Activate test run /PROGMODEDRYRUNON/ No. 63
Definitions:
Activate test run.
(VDI signal: rapid traverse override)
Not permitted if:
1. The nesting depth is too great
2. If there is a reorganize brake error
Possible actions:
1. Wait until previous ASUB has finished or cancel program
2. Cancel program
Activate user data /SET_USER_DATA/ No. 93
Definitions:
Set all user data to active.
For example, that means tool lengths newly changed via MMC
become active immediately in the current program.
Not permitted if:
1. The NCK channel status is not Stopped
2. The channel has stopped,
and the current block cannot be reorganized.
Possible actions:
1. Press stop button/single block/reset/StopAtEnd button (in Auto).
2. Activate block change until NC block can be reorganized
All MD (NEW_CONF) active /NEWCONF/ No. 48
Definitions:
Sets all machine data with the attribute (NEW_CONF) to active (PI command)
Should not occur in any alarm
All MD (NEW_CONF) active (block search) /BLOCKSEARCHRUN_NEWCONF/ No. 90
Definitions:
Set all machine data with the attribute (NEW_CONF) to active.
(NC_Satz, NEW_CONF with block search)
Should not occur in any alarm
All MD (NEW_CONF) active (program) /NEWCONF_PREP_STOP/ No. 89
Definitions:
Set all machine data with the attribute (NEW_CONF) to active.
(NC_Satz, NEW_CONF)
Should not occur in any alarm
Alarms