Hfsi Counters; Jam Counter - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

HFSI Counters

Purpose
This routine has two functions; it will reset the counter for a specific High Frequency Service
item to 0, or it can change the end-of-life threshold for that counter.
Procedure
1.
Enter UI Diagnostic mode
(Accessing UI
2.
Select Adjustment/Others.
3.
Select HFSI Counter.
4.
Select the HFSI Counter from the list on the UI, and press Details. (see
nance Activities
for a listing of HFSI items and counter numbers).
5.
To clear the counter after a replacement, select Reset Current Value.
The specified HFSI Counter is reset and the message "Job completed" is displayed on
the screen.
6.
To modify the end-of-life count, select Change Spec Life. Enter the new threshold value.
7.
Select Close to return to the Adjustment/Others screen.
General Procedures & Information
HFSI Counter, Jam Counter
Diagnostics).
Detailed Mainte-
BUS Updated 12/2011

Jam Counter

Purpose
Displays the No. of occurrences of jams from the time of reset on completion of the previous
service call up to now.
Procedure
1.
Enter the UI Diagnostic Mode
2.
Select Faults on the Maintenance / Diagnostics screen.
3.
The following Items are displayed on the Faults screen.
Current Faults
Jam Counter button
Failure Counter button
Shutdown History button
4.
Select Jam Counter.
5.
The following Items are displayed on the Jam Counter screen.
Chain-Link
Count
NOTE: •Displays failures from the last exit from the Service Mode with Exit (Clear Log)
until now.
The Count is reset when exiting from the Service Mode by using Exit (Clear Log).
6.
Select Close to return to the Faults screen.
07/2011
6-30
(Accessing UI
Diagnostics).
WorkCentre 5335 Family Service Documentation
Initial Issue

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series