B. UPLOADING CALL PROCESSING CARDS
NOTE:
tion (using an RS-232 cable), Inter-Tel recommends using the TCP/IP connection when upload-
ing the software.
Ensure that the programming PC is equipped with the DB Programming software. (See
1.
page 6-17
Press the * button while powering up the CPC to place the card in download mode. The
2.
CPU Active and DB LEDs alternately lights.
Connect one end of the Ethernet cable from the LAN or network hub to the IP port on
3.
the CPC. (See
Select Start - Inter-Tel DB Programming -
4.
appears.)
Click
5.
Enter a description, up to 40 characters, in the
6.
identify the connection type. For example, if creating a setting for the CPC on node 2,
enter Node 2 CPC.
Select
7.
Enter the appropriate upload source file name in the File box or use the
8.
to locate the file (the file ends with .bin). Make sure the complete file name appears
in the box.
Enter the IP Address or hostname of the CPC. The IP address is the device's current IP
9.
address or the default IP address that is programmed into the device's local database in
flash memory.
Enter the Username and Password required to access the CPC. The default username is
10.
CPU, and the default password is itpassw.
If necessary, enter the port number that corresponds to the CPC Web Listening Port
11.
field in DB Programming (see
ing port number; otherwise, the upload fails. By default, this is 80.
If the System has just been powered up, wait at least three minutes to allow the system
12.
to stabilize and finish printing power-up messages before performing the next step.
Click
13.
into flash memory on the CPC.
If the upload fails to start, the CPC LEDs indicate that the card is still in the download
state, and the PC displays the reason for the failure. The card remains in download
mode until the upload is attempted again. If an upload is not attempted before the
download state times out, the system resets.
When the upload is complete, the system resets and the PC displays a message indicat-
14.
ing the operation was successful. Click
Uploading Call Processing Cards
INTER-TEL
Although the CPC supports a TCP/IP network connection and a direct serial connec-
in PROGRAMMING for details.)
Figure 3-47
on
page 3-96
or select
from the File menu to create an entry.
New
New
CPU/CPC - Call Processing Cards
(or select Start from the File menu). The software is automatically uploaded
Start
®
®
AXXESS
MANUAL VERSION 11.0 – May 2008
for a drawing showing the IP port.)