NOTE:
mum operating temperature (as stated above). Therefore, when installing the chassis
and station instruments, allow a sufficient margin for error in case of air conditioning fail-
ure, routine maintenance, plant shutdown, etc. As a general rule, if conditions are suit-
able for office personnel, they are also suitable for all equipment and station instrument
operation. A properly controlled environment helps to extend the operating life of the
equipment.
From UL 1459, a product safety specification governing telephone equipment:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically designed for
wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.
B. ASSEMBLE THE NECESSARY TOOLS AND SUPPLIES
Digital and Executone
cable to run from the MDF to all station instruments and four-conductor modular jack
(line jack unit) assemblies for all station instruments, including phones, single-line
DTMF or pulse-tone sets, and playback devices (version 2.x or later is required for
pulse-tone sets). (For exceptions, see the NOTE following
NOTE:
Multi-protocol endpoints operating in SIP mode: A v1.1 or later SIP Server is
required. See the SIP Server Installation and Configuration Manual (document part no.
835.2605) for details.
Models 8664, 8665, 8668 wireless endpoints: A NetLink SVP (SpectraLink
check box Priority) server is required. See the NetLink SVP Server and Model 8664/
8665/8668 Installation Manual (document part no. 935.4521) for details.
Analog Phones: Industry-standard, three-pair (six-conductor) twisted cable to run from
the MDF to all analog phones and six-conductor modular jack (line jack unit) assem-
blies for all station instruments.
A high-impedance digital multimeter to check the power supply and ensure correct wir-
ing of the modular jack (line jack unit) assemblies. Multimeter accuracy must be ±0.5%
or better.
With a U.S. system, standard terminal blocks (66M1-50 type) and bridging clips for
constructing the MDF. With a European system, Krone blocks for the MDF jumper
field.
With a U.S. system, industry-standard, 25-pair cable for connecting the MDF terminal
blocks to the circuit cards in the equipment chassis.
Industry-standard, cross-connect wire [industry-standard jumper in Europe] may be
needed for certain applications.
Assemble the Necessary Tools and Supplies
®
INTER-TEL
AXXESS
Locate the equipment in a climate-controlled room. Do not exceed the maxi-
®
Phones: Industry-standard, one-pair (two-conductor) twisted
Executone Phones are not supported in Europe.
®
MANUAL VERSION 11.0 – May 2008
paragraph 6.5
Installation
on
page
3-16.)
®