Inter-Tel AXXESS Manual page 224

Hide thumbs Also See for AXXESS:
Table of Contents

Advertisement

Installation
®
®
INTER-TEL
AXXESS
CONNECTOR (J7)
7.31 The BRS transmit pairs connect to the receive pairs of the terminating device, without
regard for signal polarity. (The installer must determine which pairs are transmit and receive
for the terminating device.)
7.32 Install the BRS cards in the selected slot in the equipment chassis, and connect the
external power supply, if required. Also connect the 50-pin Amp connection to the front of the
card and terminate the cable to the MDF (Main Distribution Frame).
7.33 Install the BRU card in the selected slot in the equipment chassis, and connect the 50-
pin Amp connection to the front of the card, and then terminate the cable to the MDF.
NOTE:
in the default position, the jumper connects pins 5 to 6 and 7 to 8. See
133
for jumper positioning.
Page 3-38
MANUAL VERSION 11.0 – May 2008
External power supply: This power supply is provided with the device and plugs into
a wall socket.
TX
TX
RX
RX
-48V
RET
BRS
CARD
-48V
-48V RET
The jumper should have an orientation that connects the pins horizontally. For example,
TO THE DEVICE
-48V FO
-48V RET
This -48 volts is distributed on
the third pair to each BRS Device
from the MDF.
EXTERNAL 48VDC
POWER SUPPLY
(P/N 813.1740)
Connect Devices to the BRS Cards
Figure 3-63