12 Disturbance Analyzer Measurement
Meas Setup
Example
Dependencies
Preset
State Saved
Range
Initial S/W Revision
By Type of Disturbance
Specifies the disturbance list will be sorted based on type of disturbance.
Key Path
Example
Initial S/W Revision
By Time
Specifies the disturbance list will be sorted based on time.
Key Path
Example
Initial S/W Revision
Sort Order
Chooses the sorting order.
Key Path
Remote Command
Example
Dependencies
Preset
State Saved
Initial S/W Revision
1062
CALCulate:DANalyzer:DLISt:SORT:DAMPlitude ?
CALC:DAN:DLIS:SORT:DAMP PEAK
CALC:DAN:DLIS:SORT:DAMP?
Selecting the detector amplitude type to be sorted (pressing the key or sending the equivalent SCPI
command) will turn on the Auto Sort state, even if that detector amplitude type was already
selected.
PEAK
Saved in instrument state
Peak | Quasi Peak
A.14.00
Meas Setup, Disturbance List, Sort Disturbances
CALC:DAN:DLIS:SORT:TYPE TDIS
A.14.00
Meas Setup, Disturbance List, Sort Disturbances
CALC:DAN:DLIS:SORT:TYPE TIME
A.14.00
Meas Setup, Disturbance List, Sort Disturbances
CALCulate:DANalyzer:DLISt:SORT:ORDer ASCending |DESCending
CALCulate:DANalyzer:DLISt:SORT:ORDer?
CALC:DAN:DLIS:SORT:ORD DESC
CALC:DAN:DLIS:SORT:ORD?
Selecting the sort order (pressing the key or sending the equivalent SCPI command) will turn on the
Auto Sort state, even if that sort order was already selected.
ASCending
Saved in instrument state
A.14.00
EMI Receiver Mode Reference